Suggested Operating Conditions and Parameters
Class A Power amplifier of single tube (A-F)
Plate voltage
|
750
|
1000
|
1250
|
V
|
Grid voltage
|
-46
|
-61
|
-80
|
V
|
Load resistance |
8.8
|
7.6
|
9.2
|
kohms
|
Plate current
|
34
|
53
|
60
|
mA
|
Signal voltage (pk)
|
41
|
56
|
75
|
V
|
Plate resistance
|
4.4
|
3.8
|
3.6
|
kohms
|
Output power
|
5.6
|
12
|
19.7
|
W
|
Class B Power amplifier of push-pull (A-F)
Plate voltage
|
1000
|
1250
|
V
|
Grid voltage
|
-72
|
-95
|
V
|
Load resistance
|
6.9
|
9
|
kohms
|
Plate current(0 single)
|
20
|
20
|
mA
|
Plate current(max single)
|
320
|
320
|
mA
|
Signal Voltage(pk)
|
380
|
410
|
V
|
Output power
|
200
|
260
|
W
|
Class B Power amplifier of single tube (modulate coefficient shall be 1) (R-F)
Plate voltage
|
1000
|
1250
|
V
|
Grid voltage
|
-72
|
-95
|
V
|
Plate current
|
130
|
106
|
mA
|
Signal Voltage(pk)
|
125
|
125
|
V
|
Output power
|
40
|
42
|
W
|
Grid current(approx) |
5
|
1
|
mA
|
Grid power(input)(approx) |
10
|
7.5
|
W
|
Class C power amplifier of single tube (max modulate coefficient shall be 1)
Plate voltage |
750
|
1000
|
V
|
Grid voltage
|
-200
|
-260
|
V
|
Plate current
|
150
|
150
|
mA
|
Signal Voltage(pk)
|
350
|
410
|
V
|
Output power
|
65
|
100
|
W
|
Grid current (approx) |
35
|
35
|
mA
|
Grid power (input)(approx) |
12
|
14
|
W
|
Limiting Operation Conditions for Safe Nor simultaneous ratings
Class | ClassA(A-F) | A push-pull Class B(A-F) | Class B(R-F) | Class C | |
Max plate voltage | 1250 | 1250 | 1250 | 1000 | V |
Max plate dissipation | 75 | 100 | 100 | 67 | W |
Max plate current (max sig. Per tube) | 175 | 150 | 175 | mA | |
Max Grid current | 50 | mA | |||
Max plate dissipation(in) | 175 | W | |||
Max Grid voltage | -400 | V |